ABB 4 Pole RCCB Price

ABB 4 Pole RCCB Price: Selection Guide for Gujarat Panel Builders and Industrial Buyers

Searching for an ABB 4 pole RCCB price? Start by confirming the current rating, leakage sensitivity, device type and complete product reference. Two four-pole RCCBs can look similar while offering different protection characteristics, connection systems and application suitability.

Ahmedabad Electrical Corporation (AEC) supports genuine ABB switchgear procurement for panel builders, OEMs, electrical contractors and industrial maintenance teams. Through its supply network, including AIM Innovations, identified as the ABB distributor, AEC helps buyers source suitable products with clear quotations and delivery schedules across Gujarat and India.

What determines the ABB 4 pole RCCB price?

There is no single price covering every ABB four-pole RCCB. A useful quotation should specify:

  • Product family: FX200 FlexLine or another applicable ABB range.
  • Rated current: The continuous-current rating required by the circuit.
  • Residual-current sensitivity: Such as 30 mA, where appropriate.
  • Detection type: Selected for the possible residual-current waveform.
  • Connection system: Terminals, busbar compatibility and installation requirements.
  • Commercial details: Quantity, GST, freight, availability and quotation validity.

When comparing an “ABB 40A 4 pole RCCB price” with another offer, check that both quotations refer to identical specifications. Request the complete ABB order code rather than accepting “equivalent four-pole model” without technical confirmation.

What does a four-pole RCCB do?

A four-pole RCCB is commonly used in three-phase systems with a neutral. It monitors the balance of current flowing through the live conductors and disconnects when residual current reaches its operating conditions.

It provides residual-current protection, but an RCCB does not provide overload or short-circuit protection. Coordinate it with suitable overcurrent protection according to ABB’s instructions.

The ampere and milliampere markings describe different functions:

  • 40 A: The device’s rated current under specified conditions.
  • 30 mA: Its rated residual operating current.
  • 4P: Four switched poles.

A 40 A RCCB should never be treated as a circuit breaker that automatically trips when load current exceeds 40 A.

ABB FX200 FlexLine RCCBs: a closer look

ABB’s FX200 range forms part of the FlexLine system, designed to simplify distribution-board assembly.

The published range includes:

  • Two-pole and four-pole versions.
  • Rated currents of 25 A and 40 A.
  • Residual-current sensitivity of 30 mA.
  • Variants listed by ABB as Types A, F and G.
  • A test button and earth-fault indication.
  • Front-mounted QR identification for product information.
  • Integration with compatible FlexLine devices using PSX busbars.

FlexLine incorporates push-in connection technology to support faster assembly. For a panel builder handling repeat orders, compatible devices and busbars can help simplify wiring and material planning.

Confirm the exact FX204 reference, detection characteristics and Indian availability before finalising the bill of materials. Do not assume every ABB RCCB uses the same terminals or accessories.

Which ABB RCCB type suits your installation?

ABB’s wider F200 portfolio includes several residual-current protection variants. Selection depends on the connected equipment and the fault-current waveform it may produce.

  • Type AC: Detects sinusoidal AC residual currents; suitability depends on the load and applicable installation requirements.
  • Type A: Detects sinusoidal AC and pulsating DC residual currents.
  • Type F: Intended for specified applications involving mixed-frequency residual currents, including certain single-phase inverter loads.
  • Type B: Detects smooth DC residual currents as well as other specified waveforms; relevant to certain drives, converters and power-electronic equipment.
  • Selective or enhanced-immunity variants: Address particular coordination or unwanted-tripping requirements, subject to the exact device specification.

An industrial panel containing VFDs should not automatically receive the same RCCB type as a simple lighting circuit. Follow the equipment manufacturer’s guidance and the installation design.

Choose sensitivity and protection coordination carefully

A 30 mA RCD can provide additional protection against electric shock where required. It complements earthing and other protective measures; it does not replace them.

Higher-sensitivity values, such as 100 mA or 300 mA in suitable product ranges, serve different design requirements and are not substitutes for required 30 mA additional protection.

Before ordering:

  • Calculate the circuit’s design current and verify conductor capacity.
  • Check upstream overload and short-circuit protection.
  • Assess normal leakage from filters and electronic equipment.
  • Coordinate upstream and downstream RCDs for selectivity.
  • Confirm voltage, frequency, neutral arrangement and terminal compatibility.
  • Arrange installation testing and periodic checks by qualified personnel.

Investigate repeated tripping rather than simply increasing the residual-current setting.

ABB MCB, MCCB and RCBO options

Different breakers perform different jobs within a coordinated distribution system:

  • ABB S200 MCBs: Provide overload and short-circuit protection. Select current rating, pole configuration, breaking capacity and trip characteristic for the circuit.
  • B, C and D MCB characteristics: Offer different instantaneous operating thresholds. Choose against inrush current and fault-disconnection requirements.
  • ABB SACE Tmax XT MCCBs: Support industrial distribution with protection and accessory options depending on frame size and trip unit.
  • ABB RCBOs: Combine residual-current and overcurrent protection within one device.

AEC also supports enquiries for ABB contactors, overload relays, switch-disconnectors and industrial breakers. Ready-stock options are available against confirmed references and quantities.

Supply across Gujarat’s cities and industrial clusters

Delivery coverage includes major GIDC estates and nearby industrial areas:

  • Ahmedabad: Vatva, Naroda, Odhav, Kathwada, Sanand, Changodar, Bavla and Dholka.
  • Gandhinagar–Mehsana: Kalol, Chhatral, Kadi, Gozaria and Visnagar.
  • North Gujarat: Himmatnagar, Modasa, Palanpur and Deesa.
  • Vadodara: Makarpura, Nandesari, Savli, Waghodia and Por–Ramangamdi.
  • Central Gujarat: Halol, Godhra, Anand, Vithal Udyognagar and Nadiad.
  • Bharuch: Ankleshwar, Panoli, Jhagadia, Dahej and Jambusar.
  • Surat: Sachin, Pandesara, Ichhapore, Hazira, Palsana and Kadodara.
  • South Gujarat: Vapi, Sarigam, Umargam, Pardi, Valsad, Navsari and Bilimora.
  • Rajkot–Morbi: Aji, Bhaktinagar, Metoda, Shapar–Veraval, Gondal, Jetpur and Wankaner.
  • Saurashtra: Jamnagar–Dared, Bhavnagar–Chitra, Sihor, Surendranagar, Wadhwan, Junagadh, Porbandar and Veraval.
  • Kutch: Gandhidham, Anjar, Bhuj, Mundra and Bhachau.

Genuine ABB products with planned delivery

Our delivery targets are 4–5 days within Gujarat and 5–6 days to major Indian metros, subject to confirmed stock, order processing and transport availability. Pan-India supply includes Mumbai, Pune, Delhi NCR, Bengaluru, Chennai, Hyderabad and Kolkata.

For your ABB 4 pole RCCB quotation, send AEC the required rating, sensitivity, device type, quantity and delivery PIN code. Include the existing product label or panel specification when replacing equipment.

Ask for the complete reference, applicable warranty terms, GST invoice and confirmed delivery schedule. A correctly matched RCCB helps keep procurement straightforward and panel completion on schedule.